<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0">
<channel>
<title>Anhui  Xin Huan Neng Electrical Co., LTD.</title>
<link><![CDATA[http://en.ahxhn.cn/]]></link>
<description>11Anhui  Xin Huan Neng Electrical Co., LTD.</description>
<item id="1">
<title><![CDATA[Workshop environment]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=652]]></link>
<description><![CDATA[]]></description>
<pubDate>2017-02-07 08:45:37</pubDate>
</item>
<item id="2">
<title><![CDATA[Workshop environment]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=651]]></link>
<description><![CDATA[]]></description>
<pubDate>2017-02-07 08:45:01</pubDate>
</item>
<item id="3">
<title><![CDATA[Workshop environment]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=650]]></link>
<description><![CDATA[]]></description>
<pubDate>2017-02-07 08:44:19</pubDate>
</item>
<item id="4">
<title><![CDATA[Workshop environment]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=649]]></link>
<description><![CDATA[]]></description>
<pubDate>2017-02-07 08:43:17</pubDate>
</item>
<item id="5">
<title><![CDATA[Workshop environment]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=648]]></link>
<description><![CDATA[]]></description>
<pubDate>2017-02-07 08:42:40</pubDate>
</item>
<item id="6">
<title><![CDATA[Workshop environment]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=647]]></link>
<description><![CDATA[]]></description>
<pubDate>2017-02-07 08:41:59</pubDate>
</item>
<item id="7">
<title><![CDATA[Workshop environment]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=646]]></link>
<description><![CDATA[]]></description>
<pubDate>2017-02-07 08:41:22</pubDate>
</item>
<item id="8">
<title><![CDATA[Workshop environment]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=645]]></link>
<description><![CDATA[]]></description>
<pubDate>2017-02-07 08:40:39</pubDate>
</item>
<item id="9">
<title><![CDATA[Workshop environment]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=644]]></link>
<description><![CDATA[]]></description>
<pubDate>2017-02-07 08:39:55</pubDate>
</item>
<item id="10">
<title><![CDATA[Workshop environment]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=643]]></link>
<description><![CDATA[]]></description>
<pubDate>2017-02-07 08:39:02</pubDate>
</item>
<item id="11">
<title><![CDATA[Workshop environment]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=642]]></link>
<description><![CDATA[]]></description>
<pubDate>2017-02-06 17:30:12</pubDate>
</item>
<item id="12">
<title><![CDATA[Office building]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=635]]></link>
<description><![CDATA[]]></description>
<pubDate>2017-02-05 15:38:38</pubDate>
</item>
<item id="13">
<title><![CDATA[Production workshop]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=634]]></link>
<description><![CDATA[]]></description>
<pubDate>2017-02-05 15:35:34</pubDate>
</item>
<item id="14">
<title><![CDATA[Factory building]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=633]]></link>
<description><![CDATA[]]></description>
<pubDate>2017-02-05 15:34:10</pubDate>
</item>
<item id="15">
<title><![CDATA[Factory building]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=632]]></link>
<description><![CDATA[]]></description>
<pubDate>2017-02-05 15:32:17</pubDate>
</item>
<item id="16">
<title><![CDATA[Factory building]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=631]]></link>
<description><![CDATA[]]></description>
<pubDate>2017-02-05 15:27:36</pubDate>
</item>
<item id="17">
<title><![CDATA[Instrument box and instrument box]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=630]]></link>
<description><![CDATA[Instrument box and instrument box are used to protect the instrument of a tool, then the instrument box and instrument box compared to what are the links and differences? In order to let you have a more in-depth understanding of the instrument box and instrument box, let us introduce the relevant knowledge of the instrument box and instrument box.Instrument boxThe instrument box generally includes the shell, the panel, the lining board, the support and so on components, mainly protects the internal components the function. The main body of the box is made of high quality aluminum a…]]></description>
<pubDate>2017-02-05 15:11:01</pubDate>
</item>
<item id="18">
<title><![CDATA[Basic knowledge of instrument]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=629]]></link>
<description><![CDATA[Basic knowledge of instrumentDetection and process control instrumentation (usually referred to as automated instrumentation) classification methods, according to different principles can be classified accordingly. For example, by using the meter energy classification, can be divided into pneumatic, electric and hydraulic instrument instrument instrument (rare); according to the instrument combination form, can be divided into base meter, unit combination instrument and integrated control device; the installation form according to the instrument, can be divided into field instrumen…]]></description>
<pubDate>2017-02-05 15:09:51</pubDate>
</item>
<item id="19">
<title><![CDATA[Some daily maintenance methods for instrument valves]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=628]]></link>
<description><![CDATA[The process and daily maintenance of instrument and meter valveInstrument valves regularly discharge two main work, one of the sewage, and the other is a regular purge. This work should be adapted to local conditions, not all process instrumentation valves are required for periodic blowdown.1 sewageThe sewage is mainly for the differential pressure transmitter, pressure transmitter, float level gauge and other instruments, as measured medium containing dust, grease, and other small particles in the deposition of lead pressure (or pressure valve to take the deposition), directly or …]]></description>
<pubDate>2017-02-05 15:08:26</pubDate>
</item>
<item id="20">
<title><![CDATA[Some experiments on DC leakage current]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=627]]></link>
<description><![CDATA[What are the methods of DC leakage current test?1) according to the situation of the tested products, refer to the transfer test standard or preventive test procedure to determine the DC test voltage value. If the DC leakage current test is combined with the DC withstand voltage test, the DC test voltage should be used as the maximum test voltage.2, according to the size of the test voltage, field equipment conditions, select the appropriate test equipment and wiring methods, draw the test wiring diagram.3, first of all, combined with the site conditions, the reasonable arrangement…]]></description>
<pubDate>2017-02-05 15:06:28</pubDate>
</item>
<item id="21">
<title><![CDATA[The detailed classification of wire and cable - Anhui new ri]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=626]]></link>
<description><![CDATA[Wire and cable.A power cable shall have the following technical characteristics1, can withstand high working voltage and high long-term, has very excellent electrical insulation properties, so the power cable by using the voltage level can be divided into: low voltage (1 thousand volts and below), medium (6 - 35 thousand V), high pressure (66 - 330 thousand V) and ultra high voltage (500 thousand kV and above).2, able to transmit a large current (hundreds of thousands or even thousands of security), so the use of cross-sectional area of several hundred or even thousands of square m…]]></description>
<pubDate>2017-02-05 15:02:42</pubDate>
</item>
<item id="22">
<title><![CDATA[Heat resistant wire and cable categories]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=624]]></link>
<description><![CDATA[(a) wire and cable wire and cable resistance materials heat-resistant material is insulating and sheathing materials of body resin with heat resistance, the main varieties are: polyurethane (up to 155 DEG C grade), polyester (up to 135 DEG C), polyvinylidene fluoride (150 DEG C) and nylon (up to 115 DEG C) insulation or sheath material. Commonly used in communications, automotive, electrical, construction and other industries.(two) the heat resistance of ordinary cable material is improved by various means:1, heat resistance modification of rubber materialsRubber materials because …]]></description>
<pubDate>2016-08-21 14:53:01</pubDate>
</item>
<item id="23">
<title><![CDATA[Talking about the difference between national standard cable]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=623]]></link>
<description><![CDATA[In the choice of cable according to their own use of the site to choose the cable, do not covet cheap. That is cheap and can ensure the cable GB, nine out of ten are walking a fine line. Flicker is not professional do not understand the industry users. In order to enable users to more clearly understand the quality standards of cable and wire and the distinction between the national standard and non-standard. Below we combined with the actual situation of engineering users and cable industry often encountered, so that we do a simple understanding.Cables and wires are commonly used …]]></description>
<pubDate>2016-08-21 14:51:58</pubDate>
</item>
<item id="24">
<title><![CDATA[PGL AC low-voltage distribution panel]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=622]]></link>
<description><![CDATA[]]></description>
<pubDate>2016-08-21 11:06:28</pubDate>
</item>
<item id="25">
<title><![CDATA[Low voltage switchgear type GGD (fixed)]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=621]]></link>
<description><![CDATA[Name: low voltage and cabinet type GGD (fixed)Category: diesel generator and parallel seriesBrief introduction: This machine / grid system by low voltage generator, low voltage switch cabinet and machine (fixed), and machine / grid connected control device, and the outlet cabinet, star generator reactor, differential protection device optional. The whole system is combined to supply power to the load or supply power to the power grid. The Guan Jian equipment of the system is a parallel / connected control device and switch (circuit breaker).]]></description>
<pubDate>2016-08-21 11:05:35</pubDate>
</item>
<item id="26">
<title><![CDATA[ZGCK1 low voltage draw out type switch cabinet]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=620]]></link>
<description><![CDATA[1 OverviewGCKl series motor control center, is mainly composed of some combination of motor control unit, and other functional units ". These units are installed in a closed metal cabinet in the following manner. By setting the level of bus in the cabinet top, each cabinet together with a cabinet function unit is connected in parallel to the vertical bus. Four separated area cabinet consists of horizontal bus area, vertical bus area, cable area and equipment installation area, functional units are installed in the small room, when any one functional unit at the time of the accident…]]></description>
<pubDate>2016-08-21 11:04:41</pubDate>
</item>
<item id="27">
<title><![CDATA[ZGCS low voltage draw out type switch cabinet]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=619]]></link>
<description><![CDATA[1 OverviewGCS type low-voltage switchgear (hereinafter referred to as the two foot joint device) designed according to industry authorities, the majority of users and the design requirements of power unit is developed with the situation of China, with high technical performance, can adapt to the development of power market and the need to introduce low voltage switchgear products competition. The device was approved in 1996 by two co chairs in Shanghai in the year of July. By the manufacturing units and the use of electricity sector attention and affirmation.Notice of the Ministry …]]></description>
<pubDate>2016-08-21 11:03:20</pubDate>
</item>
<item id="28">
<title><![CDATA[ZGGD AC low voltage distribution cabinet]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=618]]></link>
<description><![CDATA[1 Purpose1.1 type GGD AC low voltage power distribution equipment for power plants, power stations, industrial enterprises and other power users of AC 50Hz, rated electric power distribution system lJ~380V rated current 3150A, as power, lighting and power distribution equipment power conversion, distribution and control purposes.1.2 GGD AC low-voltage distribution cabinet according to the Ministry of energy Bu Bu, the majority of users and design requirements, in line with the safety, economic, reasonable and reliable principle of the design of a new low-voltage distribution cabine…]]></description>
<pubDate>2016-08-21 11:02:41</pubDate>
</item>
<item id="29">
<title><![CDATA[MNSGck]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=617]]></link>
<description><![CDATA[MNS low-voltage switchgear, is a module combination type low voltage switch cabinet by the factory assembled by standard, conform to the technical standard of IEC439-1 "low voltage switchgear and control equipment", GB7251 "low voltage switchgear and control equipment" and other standards.Main technical parameters:Rated insulation voltage 660VRated working voltage 380660VThe maximum working current of main busbar 5500A (IP00), 4700A (IP30)Main busbar peak withstand current (1S) 100KA (EFF.VALUE)The peak current of main busbar 250KA (MAX.VALUE)Maximum working current of vertical bus…]]></description>
<pubDate>2016-08-21 11:01:47</pubDate>
</item>
<item id="30">
<title><![CDATA[PrismaLow voltage fixed switch cabinet]]></title>
<link><![CDATA[http://en.ahxhn.cn/index.php?case=archive&act=show&aid=616]]></link>
<description><![CDATA[Prisma P type fixed type low voltage switchgear (hereinafter referred to as the device) it is reasonable design, reliable performance, both beautiful and safe.The utility model is used in the low-voltage power distribution system of power plants, substations, industrial and mining enterprises, high-rise buildings, etc., and can be used as power distribution and motor control centers, capacitance compensation, etc..The device complies with IEC439-1 international standard.Main technical parameters:Rated insulation voltage 1000VRated current 630-3200ARated short-time withstand current…]]></description>
<pubDate>2016-08-21 11:01:03</pubDate>
</item>
</channel>
</rss>