SWP - LCD - M multichannel checking control instrument的产品详细介绍:
Product description:
SWP - LCD - M multi-channel instrument is suitable for the need for multiple sets of process parameters (16) or less for centralized monitoring, transfinite alarm, analog output and remote transmission of the occasion.
A, instrument features:
1, the user in accordance with the Chinese menu prompt the LCD display, can be completed through panel key input signal types and the index number of free switch, achieve universal input.
2, can choose unified alarm output, alarm output and analog output respectively, respectively.
3, with output in serial communication, two-way communication with the various input/output devices, hierarchical control system.
SWP - LCD - M series multichannel inspection measuring control instrument spectrum chart
A big screen with backlit LCD display instrument
Taken the control action
Selection of the code | 06 | 07 | 08 | 09 | 14 |
Control action | No inspection measurement display | No inspection unified control/alarm output | No inspection control/alarm output respectively | 10 all inspection measurement display | 10 all inspection unified control/alarm output |
Taken the input type
code | Input type | Measuring range | code | Input type | Measuring range | code | Input type | Measuring range |
01 | B | 400 ~ 1800 ℃ | 09 | Pt100.1 | 99.9 ~ 199.9 ℃ | 17 | 30 ~ 350 omega. | -1999~99999 d |
02 | S | 0 ~ 1600 ℃ | 10 | Cu50 | 50.0 ~ 150.0 ℃ | 18 | Special specifications | A specific user |
03 | K | 0 ~ 1300 ℃ | 11 | Cu100 | 50.0 ~ 150.0 ℃ | 19 | 4 ~ 20 mA prescribing | -1999~99999 d |
04 | E | 0 ~ 1000 ℃ | 12 | 4~20 mA | -1999~99999 d | 20 | 0 ~ 10 ma, prescribing | -1999~99999 d |
05 | T | - 200 ~ 400 ℃ | 13 | 0~10 mA | -1999~99999 d | 21 | 1 ~ 5 V prescribing | -1999~99999 d |
06 | J | 0 ~ 1200 ℃ | 14 | 1~5 V | -1999~99999 d | 22 | 0 ~ 5 V prescribing | -1999~99999 d |
07 | Wre | 0 ~ 2300 ℃ | 15 | 0~5 V | -1999~99999 d | 23 | All switch input | |
08 | Pt100 | - 200 ~ 650 ℃ | 16 | 0~20 mA | -1999~99999 d |
Taken the alarm way
Selection of the code | N | H | L |
Alarm way | No type control or alarm (can be omitted) | A limit control or limit alarm | A lower limit control or the lower limit alarm |
Taken the communication methods
Selection of the code | 0 | 2 | 4 | 8 | 9 |
Communication methods | There is no communication | RS-232 | RS-422 | RS-485 | Special specifications |
Taken the way of output
Selection of the code | 0 | 1 | 2 | 3 | 4 | 5 |
Output way | There is no output | relay | 4~20mA | 0~10mA | 1~5V | 0~5V |