Product description:
1, application
The utility model has the advantages that the utility model is suitable for measuring the number of positions or positions at the same time when the temperature gradient is not significant in the production field. The utility model is widely used in large chemical fertilizer synthetic tower, storage tank, etc..
2, the main technical parameters
Electrical outlet: M27X2, NPT3/4
Thermal response time: ≤ 8S
Diameter: Φ 3
Protection level: IP65
3, models and specifications
Type index number of temperature range of temperature measuring point protection tube material WRN-230D K0-10002-12GH30300-8001Ci18Ni9NiWRE-230DE0-6001Ci18Ni9NiWRN-430DK0-1000GH30300-8001Ci18Ni9NiWRE-430DE0-600Ci18Ni9Ni
1) thermocouple I order by agreement;
2) the rest of the protection pipe is ordered according to the agreement;
3) external protective tube users should own;