Digital display regulator
shu-zi-xian-shi-tiao-jie-yi
SWP-LED-HKLevel / volume controller
Browse:
Add Time: 2016-08-18 16:24:14
Recommendation:
SWP-LED-HKLevel / volume controller的产品详细介绍:

Product description:

The SWP-LED level <=> volume control for liquid level measurement and control <=> volume conversion for various shapes can be the instrument.

First, the main features

1, there is a wide range of display measurement, can display the entire five level measurement value and the whole volume measurement value of the eight (0--999999 word), can be accurate to the decimal point after the three (0.001) volume display.

2, the look-up table method for operation, can achieve the level of the rule <=> volume high precision conversion control.

SWP-LED volume control system based on SWP model code - HK - - - - - - - - - - - - - - - - - - 5 +8 bit level volume control size 89 160× 80mm 80× 160mm (horizontal) (vertical) 96× 96mm control 0103 control (no alarm) the output control (alarm output) communication - see "communication" output - see "output" input type - see input type "first alarm mode NHL control (or alarm, upper limit control (omitted) or lower (alarm) control or alarm alarm mode) second NHL control (or alarm, upper limit control (omitted) or lower (alarm) control or alarm) feed output NP no feed output (omitted) DC24V power supply output WT DC24V power AC90 ~ 265V power supply (SMPS) AC220V power supply (linear power supply, can be omitted) shape characteristics of S vertical horizontal display instrument display instrument (omitted) * input type: (default value) code input type code input type measuring range measurement range A4 ~ 20 mA-1999 ~ 99999dD0 ~ 5 V-1999 to 99999d this list for the maximum range, the user can not modify the two meter relay output level in the range of parameters to determine the range of B0 ~ 10 mA-1999 ~ 99999dL ~ 99999dC1 ~ -1999 resistance 5 V-1999 ~ 99999dR. The whole range of user specific control code output mode selection 0123456789 output 4 ~ 20mA0 ~ 10mA1 ~ 5V0 to code 5VSCR output SSR output SOT output. The special specification communication mode selection 02489 communication mode without communication RS-232RS-422RS-485 special specifications. Example: SWP-HK801-22-A-NN no control (or alarm) output level, volume control instrument, the input type is 4 ~ 20mA, with RS-232 communication, the control output of 4 ~ 20mA, no alarm output. The SWP-HK903-81-A-HL-P control (or alarm) output level? Volume control device, the input type is 4 ~ 20mA, relay control output, with RS-485 communication, with upper and lower alarm relay output, with DC24V feed output.