An overview,
Bolt detector is to monitor whether outdoor long distance lines disconnection device, with functions of disconnection alarm and relay dry contact output.
Second, the technical indicators
1, break instructions: when a break occurs, alarm indicator, relay contact closed.
2, relay output: normally open contacts, contact capacity: DC30V, 1 a
3, working power supply: DC24V
4, the machine power consumption: < 40 ma (DC24V)
5, power frequency voltage: isolation between input/output, input/power supply voltage is not less than 2000 v;electricity
Source/isolation between the output voltage is not less than 1000 v.
Omega 6, monitoring sensitivity: k
7, appearance size: 55 ㎜ x 75 ㎜ x 120 ㎜
8, installation methods: 35 mm guides and disk screws in two ways
Three, model
S3-KL-J
Fourth, matters needing attention
Using the environment should be no conductive dust and no corrosive action on metals, and damage the insulation gas exists, height is less than 2500 meters above sea level.