Product description:
YBS - WY intelligent pressure verification YBS - WY intelligent pressure checking instrument is my company is engaged in the production and development of new type testing instrument, its cost performance is better than the British Druck similar products of the company.Check the instrument not only solved the standard pressure, and better meet the needs of the comprehensive test on the spot.YBS - WY intelligent pressure verification accuracy of 0.1% and 0.1% two kinds, is ideal for laboratories, factories, universities of high-grade tool table, and can be used as a medium precision pressure test standard table.
The main technical indicators
Pressure range: - 95 kpa ~ 1.6 MPa
Resolution: pressure: Min 1 pa
Current: Min 1 ua
Current measuring range: 0 ~ 22 ma
Dc output: 24 VDC
The accuracy of the quasi: pressure: 0.1% f. S 0.05% F
Current: 0.05% plus or minus 1 d
Temperature range: 5 ~ 50 ℃
Dc work time: 10 hours or more
Show: 4 1/2 LCD 5 1/2 pressure, current double LCD display
Relative humidity: 80% RH or less
Overload capacity: for maximum range of 1.2 ~ 1.5 times
Dimensions: 240 x 80 x 40 mm
Weight: 2.5 Kg
Built-in battery: a charge to work 15 hours
Selection table
range | range | The resolution of the | Negative pressure | precision | precision | The stability of (one year) | Hand pump |
YBS-WY | 10KPa | 1Pa | - | 0.10% | 0.075% | ±0.1%F·S | built-in |
YBS-WY | 16KPa | 1Pa | - | 0.10% | 0.075% | ±0.1%F·S | built-in |
YBS-WY | 20KPa | 1Pa | - | 0.10% | 0.075% | ±0.1%F·S | built-in |
YBS-WY | 25KPa | 1Pa | - | 0.10% | 0.05% | ±0.075%F·S | built-in |
YBS-WY | 40KPa | 1Pa | - | 0.10% | 0.05% | ±0.075%F·S | built-in |
YBS-WY | 60KPa | 1Pa | - | 0.10% | 0.05% | ±0.075%F·S | built-in |
YBS-WY | 100KPa | 10Pa | - | 0.10% | 0.075% | ±0.075%F·S | built-in |
YBS-WY | 160KPa | 10Pa | - | 0.10% | 0.05% | ±0.075%F·S | built-in |
YBS-WY | 200KPa | 10Pa | - | 0.10% | 0.05% | ±0.075%F·S | built-in |
YBS-WY | 240KPa | 10Pa | - | 0.10% | 0.05% | ±0.075%F·S | built-in |
YBS-WY | 100KPa | 10Pa | -95KPa | 0.10% | 0.075% | ±0.075%F·S | built-in |
YBS-WY | 160KPa | 10Pa | -95KPa | 0.10% | 0.05% | ±0.075%F·S | built-in |
YBS-WY | 200KPa | 10Pa | -95KPa | 0.10% | 0.05% | ±0.075%F·S | built-in |
YBS-WY | 240KPa | 10Pa | -95KPa | 0.10% | 0.05% | ±0.075%F·S | built-in |
YBS-WY | 0.4MPa | 10Pa | - | 0.10% | 0.05% | ±0.075%F·S | built-in |
YBS-WY | 0.6MPa | 10Pa | - | 0.10% | 0.05% | ±0.075%F·S | built-in |
YBS-WY | 1MPa | 100Pa | - | 0.10% | 0.075% | ±0.075%F·S | built-in |
YBS-WY | 1.6MPa | 100Pa | - | 0.10% | 0.05% | ±0.075%F·S | built-in |
YBS-WY | 2.0MPa | 100Pa | - | 0.10% | 0.05% | ±0.075%F·S | built-in |
YBS-WY | 2.5MPa | 100Pa | - | 0.10% | 0.05% | ±0.075%F·S | built-in |
YBS-WY | 4.0MPa | 100Pa | - | 0.10% | 0.05% | ±0.075%F·S | built-in |
YBS-WY | 6.0MPa | 100Pa | - | 0.10% | 0.05% | ±0.075%F·S | built-in |
YBS-WY | 10.0MPa | 1KPa | - | 0.10% | 0.075% | ±0.075%F·S | built-in |
YBS-WY | 16.0MPa | 1KPa | - | 0.10% | 0.05% | ±0.075%F·S | built-in |
YBS-WY | 20MPa | 1KPa | - | 0.10% | 0.05% | ±0.075%F·S | The outer |
YBS-WY | 25MPa | 1KPa | - | 0.10% | 0.05% | ±0.075%F·S | The outer |
YBS-WY | 40MPa | 1KPa | - | 0.10% | 0.05% | ±0.075%F·S | The outer |
YBS-WY | 60MPa | 1KPa | - | 0.10% | 0.05% | ±0.075%F·S | The outer |
YBS-WY | 100MPa | 10KPa | - | 0.10% | 0.05% | ±0.075%F·S | The outer |
YBS-WY | 160MPa | 10KPa | - | 0.10% | 0.05% | ±0.075%F·S | The outer |
YBS-WY | 200MPa | 10KPa | - | 0.10% | 0.05% | ±0.075%F·S | The outer |