3051 h type high temperature pressure transmitter (rosemount的产品详细介绍:
Product description:
Technical parameters:
Measurable process temperature up to 375 ° F (191 ° C), and do not need to use the diaphragm seal and capillary water
Accuracy is 0.25%, the range than 100:1
Under the high temperature applications, temperature and time response
The sensing film head and circuit board is the same as the type 3051 c
model | Transmitter type (choose one) |
TY3051HD TY3051HG | Differential pressure transmitter, used for high temperature process Gauge pressure transmitter, used for high temperature process |
code | Pressure range (URL) (a) |
2 3 4 5 | 0-2.5 and 0-250 inh2o (0-0.62 to 0-62.2 kPa) 0-10 to 0-1000 inH2O (0-2.48 and 0-248 kpa) 0-3 to 0-300 psig (0-20.7 and 0-2070 kpa) 0-20 to 0-2000 psig (0-138 to 0-13800 kpa) |
code | The output |
A M(1) | 4-20 ma, with digital signal based on HART protocol 1-5 Vdc, low power consumption, with a digital signal based on HART protocol (0.8-3.2 Vdc output, with the option code C2) |
code | Process connectionProcess flange materialDrainage/exhaustFlange joint |
2 7 (2) | SSTSSTSSTHartz alloySSTSST |
code | Process isolation diaphragm |
2 3 (2) 5 | 316L SST Hartz alloy C - 276 tantalum |
code | O-rings material |
A | Glass filled tetrafluoroethylene (TFE) |
code | Process of charging |
D H N | 200 silicone d.c. Inert liquid Neobee M-20 |
code | Sensing film head isolation diaphragm material |
2 | SST |
code | Sensing head liquid membrane |
1 2 | Silicone oil Inert liquid (halogenated hydrocarbon) |
code | The shell materialConduit entrance size |
A B C D J K L | Aluminum, polyurethane coatingAluminum, polyurethane coatingAluminum, polyurethane coatingAluminum, polyurethane coatingSSTSSTSST1/2-14NPTM20×1.5(CM20)PG13.5G1/21/2-14NPTM20×1.5(CM20)PG13.5 |
(1) does not apply for the dangerous sites authentication options code I1, N1, E4 and K6.
(2) recommend materials meet NACE MR 01-75.
(2) recommend materials meet NACE MR 01-75.
code | options |
B5 B6 E5 I5 K5 C6 K6(1) I1(1) N1(1) E8 E4(1) E7 I7 L4 M5 M6 Q4 J1(2) J3(2) T1(3) C1 C2 C4(4) S4(5) P1 P2 D3 D8 | Mounting bracket 2 inch pipe installation and panel installation universal mounting bracket, carbon steel bolts 2 inch pipe installation and panel installation universal mounting bracket, SST bolt For the dangerous sites certification Manufacturer (FM) for the absolute flame-proof certification Manufacturer (FM) for the absolute nonflammable and intrinsically safe authentication Manufacturer (FM) for the absolute explosion-proof and intrinsically safe authentication Canadian standards association (CSA) explosion-proof and intrinsically safe authentication (maximum voltage 42.4 Vdc) CSA and CENELEC explosion-proof and intrinsically safe authentication BASEEFA/CENELEC essence safety certification BASEEFA N class certification CESI/CENELEC flame-proof certification Japanese industrial standard (JIS) flame-proof certification The Canadian standards association (SAA) flame-proof certification The Canadian standards association (SAA) intrinsically safe authentication Flange and joint bolt Austenitic 316 SST bolt header LCD header for aluminum shell (shell code only A, B, C) LCD header for SST shell (shell code only J, K, L) Other options Check the data Only the machine zero point adjustment Without the machine zero point or range adjustment Transient voltage protection terminal block Custom software configuration (along with the contract finish CDS00806-0100-4001) 0.8 3.2 Vdc output, a digital signal based on HART protocol (only output code M) Analog output stage in accordance with NAMUR recommended NE43, on January 18, 1994 Orifice plate and integration components connected - reference PDS00813-0100-4686 order information Hydrostatic test Clean, used for special applications A quarter - 18 NPT process connection (no flange joint) Ceramic ball drainage/exhaust valve |
M (1) does not apply to low power option code.
(2) the machine zero point and range adjustment for the standard, unless specified J1 or J3 option code.
For the dangerous sites (3) shall not apply to the authentication code or I1 K6.
(4) in the factory preset is operated in accordance with NAMUR, cannot change for the standard operation at the scene.
(5) the maximum static pressure rating of the option for 3000 psi (20684 kpa), applies only to factory assembly without connected pipeline, and limited to the range of 2, 5-tetrafluorobenzoic.
(2) the machine zero point and range adjustment for the standard, unless specified J1 or J3 option code.
For the dangerous sites (3) shall not apply to the authentication code or I1 K6.
(4) in the factory preset is operated in accordance with NAMUR, cannot change for the standard operation at the scene.
(5) the maximum static pressure rating of the option for 3000 psi (20684 kpa), applies only to factory assembly without connected pipeline, and limited to the range of 2, 5-tetrafluorobenzoic.