Special cable
tezhongdianlan
KX EX si columns such as resistance to high temperature comp
Browse:
Add Time: 2016-08-20 16:02:18
Recommendation:
KX EX si columns such as resistance to high temperature comp的产品详细介绍:

This product is suitable for the index number is S, E, K, N, E, J and T thermocouples compensating lead wires.
A, production standards The enterprise standard
Second, the product name, model as shown in table 1
Table 1


The product nameCompensation conductor modelThe name with thermocoupleWith the thermocouple index number
Copper, copper nickel compensation conductor should be 0.6SC
RC
10 - platinum platinum rhodium thermocouple
13 - platinum rhodium platinum thermocouple
S
R
Iron, copper and nickel 22 compensation conductorKCANickel chrome - nickel silicon thermocoupleK
Copper-constantan thermocouple cableKCB
Nickel chrome 10 - nickel silicon 3 extension wireKX
Iron, copper and nickel 22 compensation conductorNCNickel chrome - nickel silicon thermocoupleN
14 silicon nickel chrome - nickel silicon extension type wireNX
Nickel chrome 10-45 extended type copper silicon wiresEXCopper nickel chrome - nickel thermocoupleE
45 extended type iron, copper and nickel wireJXIron, copper and nickel thermocoupleJ
45 extended type copper, copper nickel wireTXCopper-constantan thermocoupleT


Three, use conditions of ambient temperature: 60 ~ 275 ℃.

Fourth, technical conditions
1, when the ambient air temperature is 15 ~ 35 ℃, relative humidity is no more than 80%, compensation conductor should be finished product line between the core and the line between core and shielding layer of insulation resistance for every 10 m is not less than 5 m omega.
2, finished product compensation conductor through ac 50 hz, 500 v voltage test for 1 minute not breakdown;
3, thermoelectric potential tolerances in table 2

Table 2.


modelThermoelectric emfs mu VAt 200 ℃
Thermoelectric emfstolerance
SC or RC
KCA or KCB
KX
NC
NX
EX
JX
TX
1440
8137
8137
5912
5912
13419
10777
9285

Plus or minus 60
+ 100
+ 100
+ 100
+ 100
+ 120
+ 140
+ 90


Five, the specifications of the cable and outer diameter refer to table 3

Table 3


modelWire core materialWire core typeNominal cross section wasConductor structure root/mm in diameterThe finished cable diameter
KCHFF
KCAHFF
KXHFF
NCHFF
NXHFF
EXHFF
JXHFF
TXHFF
Compensating lead wireSingle strand wire core0.2
0.5
1.0
1.5
2.5
1/0.52
1/0.8
1/1.13
1/1.37
1/1.76
1.6 x 2.4
2.1 x 3.2
2.1 x 3.2
2.7 x 4.7
3.5 x 5.9
Multi-strand wire core0.2
0.5
1.0
1.5
7/0.2
7/0.3
7/0.43
7/0.52
1.7 x 2.6
2.2 x 3.4
2.9 x 4.6
3.1 x 5.2


Note: 1, the shield type compensation wire diameter should be shielded layer thickness, namely add 0.8 mm;
2, line core core (R) or multiple thread tape screened (P), the model should add the "R" or "P" or "RP".

Six, delivery requirements
1, delivery length of 100 m, or the integer times, length should be not less than 100 m in coil, the length of the measurement error should be not more than + / - 0.5%;
2, according to the agreement to allow any length of delivery.