Special cable
tezhongdianlan
Power cable
Browse:
Add Time: 2016-08-20 16:16:00
Recommendation:
Power cable的产品详细介绍:

Product description:



A, product introductionPower cable in transmission and distribution system, this company produces the ac rated voltage 0.6/1 kv PVC insulated power cable and crosslinked xlpe power cables, 35 kv and below its performance not only conforms to the standard GB1276 and "and IEC60840, and has formed series, namely, flame retardant, fire-resistant type, cold type and waterproof of power cable.In flame retardant series products, has been successfully used in the oxygen isolation technology, not only 0.6/1 kv flame retardant PVC insulated and cross-linked polyethylene insulation of power cable can achieve GB/T12666.5 "into A bunch of power cable fire test method" in class A, and rated voltage up to and including 6/10 kv 6/10 kv crosslinked polyethylene resistance can meet the requirements of class A high flame retardant cable and A large margin.High in cross-linked polyethylene insulation flame retardant and developed on the basis of the low smoke zero halogen flame retardant high oxygen insulation layer of power cable, low smoke zero halogen performance meet the national standards GB/T17651.1.2 and GB/T17650.1.2.So that the company's overall level of crosslinking polyethylene cable is lower than the domestic leading position.This company produces the refractory type power cable of rated voltage 0.6/1 kv copper core cable, can also produce low smoke zero halogen fire-resistant power cable, high flame retardant fire-resistant power cable, oxygen insulation layer the fireproof performance in line with the GB/T12666.6 cable fire resistance test method.Series of fire-resistant power cable, therefore, the overall excellent performance and reliable.Block water performance of fire retardant cable comply with the regulations of IEC502-2.Second, the cable type, name, and USES

Order no.


Type no.


The name says


Using range


1


VV VLV
VY VLY


PVC insulated PVC/PE sheathed power cable


For laying indoors, in tunnel and pipeline, the cable is unable to bear external mechanical forces


VV22 VLV22
VV23 VLV23


PVC insulated PVC/PE sheath steel tape armoured power cables


For laying indoors, in tunnel buried in soil, the cable is able to bear external mechanical forces.


VV32 VLV32
VV33 VLV33
VV42 VLV42
VV43 VLV43


PVC insulated PVC/PE sheathed steel wire armoured power cables


In high head area, cable able to bear external mechanical forces and considerable tension.


2


YJV YJLV
YJY YJLY


Cross-linked polyethylene insulation PVC/PE sheath steel tape armoured power cables


For laying indoors, in tunnel and pipeline, the cable is unable to bear external mechanical forces.


YJV22 YJLV22
YJV23 YJLV23


Cross-linked polyethylene insulation PVC/PE sheath steel tape armoured power cables


For laying indoors, in tunnel buried in soil, the cable is able to bear external mechanical forces.


YJV32 YJLV32
YJV33 YJLV33
YJV42 YJLV42
YJV43 YJLV43


Cross-linked polyethylene insulation PVC/PE sheathed steel wire armoured power cables


In high head area, cable able to bear external mechanical forces and considerable tension.

Note: ZR - flame retardant G - NH - oxygen insulation layer refractory


Three, the production scope



model


some


Nominal section (was)



model


some


Nominal section (was)


Rated voltage (KV)



Rated voltage (KV)


0.6/1



0.6/1


6/6 (6/10)
8.7/10 (8.7/15)
26/35 (26/45)


CU


AL



CU


AL


CU


AL


VV
VLV
VY
VLY


1
2


1.5 ~ 1200
1.5 ~ 300


4-1200
4-300


YJV
YJLV
YJY
YJLY


1
2


1.5 ~ 1200
1.5 ~ 300


4-1200
4-300


25 ~ 500


35 ~ 630


3
4


1.5 ~ 300
1.5 ~ 300


4-300
4-300


3
4


1.5 ~ 300
1.5 ~ 300


4-300
4-300


25 ~ 400


35 ~ 400


5
3 + 1


1.5 ~ 300
1.5 ~ 300


4-300
4-300


5
3 + 1


1.5 ~ 300
1.5 ~ 300


4-300
4-300


 


 


3 + 2
4 + 1


1.5 ~ 300
1.5 ~ 300


4-300
4-300


3 + 2
4 + 1


1.5 ~ 300
1.5 ~ 300


4-300
4-300


 


 


VV22
VLV22
VV23
VLV23


1
2


10 to 500
2.5 ~ 300


16 ~ 500
4-300


YJV22
YJLV22
YJV23
YJLV23


1
2


10 to 500
2.5 ~ 300


16 ~ 500
4-300


25 ~ 400


35 ~ 400


3
4


2.5 ~ 300
2.5 ~ 300


4-300
4-300


3
4


2.5 ~ 300
2.5 ~ 300


4-300
4-300


25 ~ 400


35 ~ 400


5
3 + 1


2.5 ~ 300
2.5 ~ 300


4-300
4-300


5
3 + 1


2.5 ~ 300
2.5 ~ 300


4-300
4-300


 


 


3 + 2
4 + 1


2.5 ~ 300
2.5 ~ 300


4-300
4-300


3 + 2
4 + 1


2.5 ~ 300
2.5 ~ 300


4-300
4-300


 


 


VV32
VLV32
VV42
VLV42
VV33
VLV33
VV43
VLV43


1
2


50 ~ 500
35 ~ 300


50 ~ 500
50 ~ 300


YJV
YJLV32
YJV42
YJLV42
YJV33
YJLV33
YJV43
YJLV43


1
2


50 ~ 500
35 ~ 300


50 ~ 500
50 ~ 300


25 ~ 400


35 ~ 400


3
4


25 ~ 300
25 ~ 300


35 ~ 300
35 ~ 300


3
4


25 ~ 300
25 ~ 300


35 ~ 300
35 ~ 300


25 ~ 400


35 ~ 400


5
3 + 1


25 ~ 300
25 ~ 300


35 ~ 300
35 ~ 300


5
3 + 1


25 ~ 300
25 ~ 300


35 ~ 300
35 ~ 300


 


 


3 + 2
4 + 1


25 ~ 300
25 ~ 300


35 ~ 300
35 ~ 300


3 + 2
4 + 1


25 ~ 300
25 ~ 300


35 ~ 300
35 ~ 300



Return To The Top