Welcome to Anhui Xin Huan Neng Electrical Co., LTD.
    RSS | Site map|disclaimer|中文版
Anhui  Xin Huan Neng Electrical Co., LTD.
freephone

0550-7989777

Popular Keywords:
联系我们
    全国咨询热线:0550-7989777
  • Mobile:18019898888
  • Email:xhn@ahxhn.cn
  • Address:69, second road, Tianchang economic development zone, Anhui province
Temperature transmitter
wendubiansongqi
LCD type intelligent temperature transmitter
Browse:
Add Time: 2016-08-21 09:41:30
Recommendation:
LCD type intelligent temperature transmitter的产品详细介绍:

Product description:


properties

Single or dual input thermocouple, heat resistance signal, single or double line analog output isolation of current or voltage signal, and improve electrical isolation between input, output, power performance.


Technical characteristics

This product USES the advanced digital technology, with the traditional analog instrument does not have a number of advanced performance, in both the restraint of the high and low frequency interference signal with excellent performance, even can still reliable application in high power frequency conversion control system, at the same time, the application of digital technology completely overcomes the drawback of traditional linear differential temperature transmitter, internal adopt digital calibration, not zero and full automatic potentiometer, automatic zero dynamic calibration, temperature drift compensation and so on many advanced technologies, and accord with IEC61000-4 - now defined in 95 the fourth class () bad industrial site environment of anti electromagnetic interference for the product, this series of technical application make the stability and reliability of the product guarantee of science.

This product is also adopted the measurement, the output value of synchronous LCD digital display technology, can online observation of actual input and output value theory, at the same time realize the online fault diagnosis, the above technology leading the international advanced level.


applicability

In unit combination instrument and DCS, PLC systems, such as in oil field, electric power, metallurgy, petrochemical, manufacture industry has been widely applied in major projects.


Technical parameters

The transmission system accuracy: & plusmn;0.2% & times;F·s.

Temperature drift: & le;0.005% F·S / ℃

LCD digital display: double rows, according to the four floating-point decimal.

Display resolution: & plusmn;Take a word

Cold junction compensation accuracy: & plusmn;1 ℃

When measuring thermal resistance allows the lead resistance: & le;50 & Omega;

Working temperature: industrial standard - 10 ~ + 55 ℃

Allow external load impedance output current:

4-20 ma output 0-500 & Omega;;0 to 10 0 and 1 k & Omega; the output of the ma, need more load capacity when ordering, please.

Electromagnetic compatibility: meet IEC61000-4 - and in 95 the fourth category specified in (a) bad industrial site of anti electromagnetic interference for environment on the product.

Input/output/power/communication/dual insulation intensity: & ge;1500 v ac

Storage and transportation environment temperature: - 40 ~ + 80 ℃

Relative humidity: 10-90% RH (40 ℃)

Power supply:

Communication: AC 95-265 - v

DC: DC 12-32 v (reverse connect protection)

Input power: 0.9 1.8 W (associated with types, see the product manual about the calculation method of the input power of the appendix)

Communication interface: RS232 or RS485, MODBUS protocol software (optional).

Overall dimensions: width & times;High & times;Deep: 22.5 & times;100 & times;115 mm

Net weight: 140 g & plusmn;20 g

spectrum

model
instructions
PWDA-
×
×
×
×
×
LCD digital display temperature
The input circuit




The default for single loop
D




Double circuit (isolated)
The first output all the way
1



4-20mA
2



1-5V
3



0-10mA
4



0-5V
5



0-10V
The first two output


The default is no second output
1


4-20mA
2


1-5V
3


0-10mA
4


0-5V
5


0-10V
communication
T1

RS485
T2

RS235
The power supply mode
The default for ac 220 v
D
24 v dc

When ordering, please specify the input signal types:

Thermocouple: K, E, S, B, J, R, N

Thermal resistance: Pt100, Cu100, Cu50, BA1, BA2

Other types of input, output, otherwise special custom-made.

Description:

1, single loop input can have at most two lines of output, double input every road can only corresponding to output all the way;

2, including communication function of the product, analog can only single into a single, or double input and analog output.

The output of the input signal failure state

Input signal failure including input fault (including open circuit and short circuit) and the outrange two kinds of fault state, the corresponding display information, please see & other;Liquid crystal display information & throughout;In the introduction.

Input output state setting method of failure:

In the following graphic method set up dial the code switch (black switch convex) :


Return To The Top