Welcome to Anhui Xin Huan Neng Electrical Co., LTD.
    RSS | Site map|disclaimer|中文版
Anhui  Xin Huan Neng Electrical Co., LTD.
freephone

0550-7989777

Popular Keywords:
联系我们
    全国咨询热线:0550-7989777
  • Mobile:18019898888
  • Email:xhn@ahxhn.cn
  • Address:69, second road, Tianchang economic development zone, Anhui province
Electrical equipment cable
dian-qi-zhuang-bei-yong-dian-lan
Flame retardant in the cable
Browse:
Add Time: 2016-08-21 15:17:02
Recommendation:
Flame retardant in the cable的产品详细介绍:

Product description:


The product is suitable for use in petroleum, chemical industry and other departments of the intrinsically safe equipment and system, it not only can transmit weak analog signals and digital signals.And the anti-jamming performance of the cable is high, electric performance is stable.Ensures the accuracy of the transmitted signal parameters and the safe running of the control system.A, flame retardant testing instrument cables for the security system1, the performance characteristics:A, cable long-term working temperature: 70 ℃B, the lowest temperature: - 40 ℃C, cable laying temperature: not below 0 ℃D, laying allowed bending radius: not less than 6 times outer diameter, armored cable should be not less than 12 times of cable diameterE, rated voltage: 300/500 v2, cable type, name, scope of application:Type no.The name saysScope of applicationZR-BAVVP3Copper core PVC insulated aluminum-plastic composite belt total shielding PVC sheathed with instrumentation cable intrinsically safe systemBridge layingZR-BAVP3VCopper core PVC insulated aluminum-plastic composite belt to wring shielding PVC sheathed with instrumentation cable intrinsically safe systemBridge layingZR-BAVP3VP3Copper core PVC insulated aluminum-plastic composite belt to wring shielding aluminum-plastic composite belt total shielding PVC sheathed with instrumentation cable intrinsically safe systemBridge layingZR-BAVVP3/22Copper core PVC insulated aluminum-plastic composite belt always BingBiGang armored PVC sheathed with instrumentation cable intrinsically safe systemBuried layingZR-BAYVP3Copper (PVC insulated aluminum-plastic composite tape screened PVC sheathed with instrumentation cable intrinsically safe systemBridge layingZR-BAYP3VCopper (PVC insulated aluminum-plastic composite belt to wring shielding PVC sheathed with instrumentation cable intrinsically safe systemBridge layingZR-BAYP3VP3Copper poly (PVC insulated aluminum-plastic composite belt to wring shielding aluminum-plastic composite belt total shielding PVC sheathed with instrumentation cable intrinsically safe systemBridge layingZR-BAYVP3/22Copper core PVC insulated aluminum-plastic composite belt total shielding gathering chlorine PVC sheath steel tape armoured with instrumentation cable intrinsically safe systemBuried layingZR-BAYJVP3Copper crosslinked poly (PVC insulated aluminum-plastic composite belt total shielding PVC sheathed testing instrument cables for intrinsically safe systemBridge layingZR-BAYJP3VCopper crosslinked poly (PVC insulated aluminum-plastic composite belt to wring shielding PVC sheathed testing instrument cables for intrinsically safe systemBridge layingZR-BAYJP3VP3Copper crosslinked poly (PVC insulated aluminum-plastic composite belt to wring shielding aluminum-plastic composite belt total shielding PVC sheathed testing instrument cables for intrinsically safe systemBridge layingZR-BAYJVP3/22Copper crosslinked poly (PVC insulated aluminum-plastic composite belt always BingBiGang PVC sheathed control with instrumentation cable sheath intrinsically safe systemBuried laying3, specificationmodelRated voltage (V)logarithmicNominal section (was)ZR-BAVVP3ZR-BAVVP3/22ZR-BAYVP3300/5001-600.5, 0.75 1.0, 1.5, 2.5ZR-BAYVP3/22ZR-BAYJVP3ZR-BAYJVP3/22300/5002-600.5, 0.75 1.0, 1.5, 2.5

Return To The Top