Browse: | |
---|---|
Add Time: | 2016-08-21 15:29:08 |
Recommendation: |
A: product features and uses
General use of PVC insulated and sheathed compensation wire or cable with moisture, abrasion resistance and excellent flame retardant properties; high temperature resistant fluorine plastic insulated and sheathed compensation wire or cable by continuous extrusion process, more high temperature, cold, acid and alkali water, non flammable, anti-aging and other advantages, product quality is higher than the national standard (equivalent to the GB/T4989-94 IEC584-3) regulations.
With the compensation wire or cable with low capacitance and inductance material structure of intrinsically safe explosion-proof temperature testing system, with explosion-proof safety performance, applicable to the environment under the risk of explosion proof thermocouple cold short and explosion-proof instrument connection, the formation of intrinsically safe thermocouple system.
Two: product implementation standards
GB/T4989-94 (equivalent to IEC584-3 standard)
Three: use characteristics
1 conductor maximum working temperature: heat resistant level: poly (ethylene propylene glycol) (F46) 200 c
Soluble PTFE 260 DEG C
Silicone rubber 180 DEG C
Ordinary grade: PVC 70 DEG C and 105 C, cross-linked polyethylene at 90 C
Low smoke halogen free flame retardant polyolefin 70 DEG C, crosslinking type 90 DEG C and 125 C
2 low ambient temperature: PVC sheath: fixed -40 C, non fixed laying -15 C
Fluorine plastic insulation and sheath: fixed laying -60 C, non fixed laying -20 C
3 bending radius allowed by cable: non armoured cable is 6 times the diameter of the smallest
The copper shielding steel tape armoured cable or point for a minimum of 12 times of cable diameter
Fluorine plastic insulation and sheath minimum of 10 times the diameter of the cable
Four: basic model and name
1: thermocouple compensation wire
KX-GA-VV
PVC insulated PVC sheathed precision grade K index number thermocouple compensation wire
KX-GA-VVR
PVC insulated PVC sheathed precision grade K index number thermocouple compensation flexible wire
KX-GA-VVP
PVC insulated PVC sheathed copper wire woven shielding precision thermocouple compensation wire, K index
KX-GA-VVRP
PVC insulated PVC sheathed copper wire woven shielding thermocouple precision K indexing, soft wire compensation
KX-HA-FF
Fluorine plastic insulated and sheathed precision grade K index number thermocouple compensation wire
KX-HA-FFR
Fluorine plastic insulated and sheathed precision grade K index number thermocouple compensation flexible wire
KX-HA-FFP
Fluoroplastic insulated and sheathed copper wire woven shielding precision thermocouple compensation wire, K index
KX-HA-FFRP
Fluoroplastic insulated and sheathed copper wire woven shielding thermocouple precision K indexing, soft wire compensation
KX-HA-FG
Fluorine plastic insulated silicon rubber sheath precision grade K index number thermocouple compensation wire
KX-HA-FGR
Fluorine plastic insulated silicon rubber sheath precision grade K index number thermocouple compensation flexible wire
KX-HA-FGP
Fluorine plastic insulated silicon rubber sheathed copper wire woven shielding precision thermocouple compensation wire, K index
KX-HA-FGRP
Fluorine plastic insulated silicon rubber sheathed copper wire woven shielding thermocouple precision K indexing, soft wire compensation
KX-HA-FV
Fluorine plastic insulated PVC sheath precision grade K index number thermocouple compensation wire
KX-HA-FVR
Fluorine plastic insulated PVC sheath precision grade K index number thermocouple compensation flexible wire
KX-HA-FVP
Fluorine plastic insulated PVC sheathed copper wire woven shielding precision thermocouple compensation wire, K index
KX-HA-FVRP
Fluorine plastic insulated PVC sheathed copper wire woven shielding thermocouple precision K indexing, soft wire compensation
KX-GA-YJV
XLPE insulated PVC sheathed precision grade K index number thermocouple compensation wire
KX-GA-YJVR
XLPE insulated PVC sheathed precision grade K index number thermocouple compensation flexible wire
KX-GA-YJVP
XLPE insulated PVC sheathed copper wire woven shielding precision thermocouple compensation wire, K index
KX-GA-YJVRP
Low smoke halogen-free insulated and sheathed copper wire woven shielding thermocouple precision K indexing, soft wire compensation
KX-GA-YDYD
Low smoke halogen free insulation and sheath precision grade K index number thermocouple compensation wire
KX-GA- YDYD R
Low smoke halogen free insulation and sheath precision grade K index number thermocouple compensation flexible wire
KX-GA- YDYD P
Low smoke halogen-free insulated and sheathed copper wire woven shielding precision thermocouple compensation wire, K index
KX-GA- YDYD RP
Low smoke halogen-free insulated and sheathed copper wire woven shielding thermocouple precision K indexing, soft wire compensation
Note: the above models are only listed in KX, such as SC, KC, EX, BC, TX, JX simply change the first item can be,
Flame retardant compensation wire type before adding ZR, ZR192 for imported PFA material,
The shield can be used tinned copper wire shield.