SWP - LED ac/dc electrical table的产品详细介绍:
Product description: |
SWP - LED series ac power concentration measurement display control instrument used for measuring signal sampling the voltage and current transformer, measuring frequency, voltage and current and power factor and single-phase active power P = U, I, Cos phi or three-phase active power P = A, instrument types SWP - W - ac power meter SWP - HZ - power frequency communication cycle counter SWP - AC - AC voltage/current meter SWP - COS - ac power factor table SWP - E - ac power concentrated display control device SWP - DC - DC voltage/current meter Second, the main characteristics 1, can arbitrarily change the instrument input signal range.No jumper wire using the latest technology, need to set the instrument internal parameters, can adapt to the requirements. 2, with output analog quantity all the way to send or alarm relay output, suitable for all kinds of measurement control. 3, the total isolation technology. 4, SWP - E series instrument can display four groups at the same time ac electrical parameters. Three, instrument appearance and wiring diagram (please see the following as the basic wiring, special order random wiring diagram) modelSWP - W, AC/DC, COS, HZ40 seriesThe wiring diagramInstrument appearanceInstrument size: 96 x 48 x 110 mmHole size: 92 * 44 mmWeight: 240 gInstrument appearanceInstrument size: 48 * 96 * 110 mmHole size: 44 * 92 mmWeight: 240 gmodelSWP - W, AC/DC, COS, HZ80 seriesThe wiring diagramInstrument appearanceInstrument size: 160 * 80 * 140 mmHole size: 152 x 76 mmWeight: 400 gInstrument appearanceInstrument size: 80 * 160 * 140 mmHole size: 76 x 152 mmWeight: 400 gmodelSWP - E80 seriesInstrument appearanceInstrument size: 160 * 80 * 140 mmHole size: 152 x 76 mmWeight: 400 gInstrument appearanceInstrument size: 80 * 160 * 140 mmHole size: 76 x 152 mmWeight: 400 gmodelSWP - W, AC/DC, COS, HZ90 seriesThe wiring diagramInstrument appearanceInstrument size: 96 * 96 * 140 mmHole size: 92 x 92 mmWeight: 400 g Four, SWP - LED series ac power concentrated display controller spectrum chart Type no.codeSaid MingSWP - E□ □ □□ -□ □-□□- □ □- □ - □Ac power concentrated display control device (only 80 series)SWP - W□ □ □□ -□ □-□□- □ □- □ - □Ac power meter SWP - AC□ □ □□ -□ □-□□- □ □- □ - □Ac voltage/current meter SWP - COS□ □ □□ -□ □-□□- □ □- □ - □Ac power factor table SWP - HZ□ □ □□ -□ □-□□- □ □- □ - □Ac power frequency cycle counterSWP - DC□ □ □□ -□ □-□□- □ □- □ - □Dc voltage/current meter Shape featuresCSHorizontal type display instrumentVertical display instrumentOverall dimensions48996 x 48 mm (swing) 48 (vertical) x 96 mm160 x 80 mm (horizontal type) 160 (vertical) x 160 mm96×96mmControl action0103Measurement according toThe three type controlCommunication methods-Zero: no communication;2: RS - 232;4: RS - 422;8: RS - 485.Output way-See "analog output way"Input typetwentySee "input type"The first alarm way-See "alarm output way"The second alarm way-See "alarm output way"Feed outputPDC24V feed outputThe power supply modeWT DC24V power supplyAC90 ~ 265 v power supply switch power supplyAC220V power supply, linear power supply, can be omitted)Note: the overall dimensions of 4 and 9 of the instrument can't do at the same time, the lower limit alarm and analog output.Example: if the instrument to do upper and lower limit alarm cannot change to the output.If you want to change to send output that there can be only one upper limit alarm. Taken the SWP - W ac power meter standard factory is double screen. Taken the input type: (factory default) codeThe input rangecodeThe input rangecodeThe input rangecodeThe input range010 ~ 1A040 ~ 4A070 ~ 200V100 ~ 500V020 ~ 2A050 ~ 5A080 ~ 300V110 ~ 600V030 ~ 3A060 ~ 100V090 ~ 400V U note: the maximum is 600 v ac voltage input signal.Such as the input voltage is greater than 600 v, must meet transformer outside.Taken the analog output mode:Selection of the code023458Output wayThere is no output4~20mA0~10mA1~5V0~5VSpecial specifications u Alarm way Selection of the codeNHLOutput wayNo alarm (can be omitted)Upper limit alarmThe lower limit alarmWhen the instrument is used for three-phase symmetrical load, wiring method is as follows:Taken the instrument used in single-phase load measurement, wiring method is as follows:U type, for example:①SWP-EC-801-02-05-NAc power concentrated display control device, input type of 0 ~ 5 a, no communication, 4 ~ 20 ma analog output, alarm output, no communication.②SWP-AC-C903-81-05-H-PAc voltmeter, input type is 0 ~ 5 a, relay control output, with RS - 485 communication, with maximum relay alarm output, with DC24V feed output. |
On A:SWP - LCD - A/M manual operator
Next:No