Product description: |
A: the product characteristics and USES General use PVC insulated and sheathed with excellent compensation wire or cable moistureproof, abrasion resistance and flame retardant properties;High temperature resistant fluorine plastic wire or cable insulation and sheath compensation adopts the continuous extrusion process, more high temperature resistant, cold resistant, resistant to acid and alkali oil and water, no secondary, anti-aging and other advantages, product quality is higher than the national standardGB/T4989-94 (equivalent to the IEC584-3). Intrinsically safe explosion-proof temperature measuring system with compensation wires or cables with low capacitance, low inductance materials structure, with explosion-proof safety performance, applicable to the environment with explosion danger operating explosion-proof thermocouple cold short and explosion-proof thermometer table joins, formed in the thermocouple temperature measurement system. 2: product standards GB/T4989-94 (equivalent to the IEC584-3 standard) Three: use the feature 1. The highest working temperature conductor: heat, fep (F46) 200 ℃ Soluble ptfe 260 ℃ Silicone rubber is 180 ℃ Regular grade: polyvinyl chloride (PVC) 70 ℃ and 105 ℃, crosslinked polyethylene 90 ℃ 70 ℃, low smoke zero halogen flame retardant polyolefin crosslinking type 90 ℃ and 125 ℃ 2. Low temperature: PVC sheathed: fixed installation to 40 ℃, the fixed installation to 15 ℃ Fluorine plastic insulation and sheath: fixed installation - 60 ℃, the fixed installation - 20 ℃ 3. Cable allows bending radius: the armoured cable minimum diameter6 times Copper tape screened or steel tape armoured deck cable minimum 12 times of cable diameter Fluorine plastic insulated and sheathed cable diameter is minimumTen times Four: the basic model and name 1: thermocouple with compensation lead |
KX-GA-VV | PVC insulated PVC sheathed precision levelKDividing thermocouple compensating conductor |
KX-GA-VVR | PVC insulated PVC sheathed precision levelKDividing thermocouple compensation soft wire |
KX-GA-VVP | PVC insulated PVC sheathed wire braided shielding precision levelKDividing thermocouple compensating conductor |
KX-GA-VVRP | PVC insulated PVC sheathed wire braided shielding precision levelKDividing thermocouple compensation soft wire |
KX-HA-FF | Fluorine plastic insulation and sheath precision levelKDividing thermocouple compensating conductor |
KX-HA-FFR | Fluorine plastic insulation and sheath precision levelKDividing thermocouple compensation soft wire |
KX-HA-FFP | Fluorine plastic insulated and sheathed wire braided shielding precision levelKDividing thermocouple compensating conductor |
KX-HA-FFRP | Fluorine plastic insulated and sheathed wire braided shielding precision levelKDividing thermocouple compensation soft wire |
KX-HA-FG | Fluorine plastic insulation silicone rubber sheath precision levelKDividing thermocouple compensating conductor |
KX-HA-FGR | Fluorine plastic insulation silicone rubber sheath precision levelKDividing thermocouple compensation soft wire |
KX-HA-FGP | Fluorine plastic insulation silicone rubber sheath copper wire braided shielding precision levelKDividing thermocouple compensating conductor |
KX-HA-FGRP | Fluorine plastic insulation silicone rubber sheath copper wire braided shielding precision levelKDividing thermocouple compensation soft wire |
KX-HA-FV | Fluorine plastic insulated PVC sheathed precision levelKDividing thermocouple compensating conductor |
KX-HA-FVR | Fluorine plastic insulated PVC sheathed precision levelKDividing thermocouple compensation soft wire |
KX-HA-FVP | Fluorine plastic insulated PVC sheathed wire braided shielding precision levelKDividing thermocouple compensating conductor |
KX-HA-FVRP | Fluorine plastic insulated PVC sheathed wire braided shielding precision levelKDividing thermocouple compensation soft wire |
KX-GA-YJV | Cross-linked polyethylene insulated PVC sheathed precision levelKDividing thermocouple compensating conductor |
KX-GA-YJVR | Cross-linked polyethylene insulated PVC sheathed precision levelKDividing thermocouple compensation soft wire |
KX-GA-YJVP | Cross-linked polyethylene insulated PVC sheathed wire braided shielding precision levelKDividing thermocouple compensating conductor |
KX-GA-YJVRP | Low smoke zero halogen insulation and sheath copper wire braided shielding precision levelKDividing thermocouple compensation soft wire |
KX-GA-YDYD | Low smoke zero halogen insulation and sheath precision levelKDividing thermocouple compensating conductor |
KX-GA- YDYD R | Low smoke zero halogen insulation and sheath precision levelKDividing thermocouple compensation soft wire |
KX-GA- YDYD P | Low smoke zero halogen insulation and sheath copper wire braided shielding precision levelKDividing thermocouple compensating conductor |
KX-GA- YDYD RP | Low smoke zero halogen insulation and sheath copper wire braided shielding precision levelKDividing thermocouple compensation soft wire |
Note: the above model list onlyKXOther such as,SC、KC、EX、BC、TX、JXOnly need to change the model first, Flame retardant models before plus compensation conductorZR,ZR192For the importPFAMaterial, Shielding can use tin plated copper wire shielding. |
2: this type thermocouple with compensation lead
IA-KX-GA-YVP | Polyethylene insulated PVC sheathed wire braided shielding precision levelKDividing the Ann thermocouple compensating conductor |
IA-KX-GA-YVRP | Polyethylene insulated PVC sheathed wire braided shielding precision levelKDividing the Ann thermocouple compensation soft wire |
IA-KX-HA-FFP | Fluorine plastic insulated and sheathed wire braided shielding precision levelKDividing the Ann thermocouple compensating conductor |
IA-KX-HA-FFRP | Fluorine plastic insulated and sheathed wire braided shielding precision levelKDividing the Ann thermocouple compensation soft wire |
IA-KX-HA-FGP | Fluorine plastic insulation silicone rubber sheath copper wire braided shielding precision levelKDividing the Ann thermocouple compensating conductor |
IA-KX-HA-FGRP | Fluorine plastic insulation silicone rubber sheath copper wire braided shielding precision levelKDividing the Ann thermocouple compensation soft wire |
Note: the above model list onlyKXOther such as,SC、KC、EX、NC、TX、JXOnly need to change the model first, Flame retardant added in front of the modelZR,ZR192For the importPFAMaterial, Shielding can use tin plated copper wire shielding. |
3: compensation cable
KX-GA-VVP | PVC insulated and sheathed wire braided shielding precision levelKDividing number of thermocouple compensating cable |
KX-GA-VVRP | PVC insulated and sheathed wire braided shielding precision levelKDividing thermocouple with compensation soft cable |
KX-GA-VPVP | PVC insulated and sheathed wire woven split screen aggregation shielding precision levelKDividing number of thermocouple compensating cable |
KX-GA-VPVRP | PVC insulated and sheathed wire woven split screen aggregation shielding precision levelKDividing thermocouple with compensation soft cable |
KX-GA-YJVP | Cross-linked polyethylene insulated PVC sheathed wire weaving total shielding precision levelKDividing number of thermocouple compensating cable |
KX-GA-YJVRP | Cross-linked polyethylene insulated PVC sheathed wire weaving total shielding precision levelKDividing thermocouple with compensation soft cable |
KX-GA-YJPVP | Cross-linked polyethylene insulated PVC sheathed wire woven split screen aggregation shielding precision levelKDividing number of thermocouple compensating cable |
KX-GAYJPVRP | Cross-linked polyethylene insulated PVC sheathed wire woven split screen aggregation shielding precision levelKDividing thermocouple with compensation soft cable |
KX-HA-FFP | Fluorine plastic PVC insulation and sheath copper wire braided shielding precision levelKDividing number of thermocouple compensating cable |
KX-HA-FFRP | Fluorine plastic PVC insulation and sheath copper wire braided shielding precision levelKDividing thermocouple with compensation soft cable |
KX-HA-FPFP | Fluorine plastic insulated and sheathed wire woven split screen aggregation shielding precision levelKDividing number of thermocouple compensating cable |
KX-HA-FPFRP | Fluorine plastic insulated and sheathed wire woven split screen aggregation shielding precision levelKDividing thermocouple with compensation soft cable |
KX-HA-FVP | Fluorine plastic PVC insulated PVC sheathed wire braided shielding precision levelKDividing number of thermocouple compensating cable |
KX-HA-FVRP | Fluorine plastic PVC insulated PVC sheathed wire braided shielding precision levelKDividing thermocouple with compensation soft cable |
KX-HA-FPVP | Fluorine plastic insulated PVC sheathed wire woven split screen aggregation shielding precision levelKDividing number of thermocouple compensating cable |
KX-HA-FPVRP | Fluorine plastic insulated PVC sheathed wire woven split screen aggregation shielding precision levelKDividing thermocouple with compensation soft cable |
KX-HA-FGP | Fluorine plastic PVC insulated silicone rubber sheathed copper wire braided total shielding precision levelKDividing number of thermocouple compensating cable |
KX-HA-FGRP | Fluorine plastic PVC insulated silicone rubber sheathed copper wire braided total shielding precision levelKDividing thermocouple with compensation soft cable |
KX-HA-FPGP | Fluorine plastic insulation silicone rubber sheath copper wire woven split screen aggregation shielding precision levelKDividing number of thermocouple compensating cable |
KX-HA-FPGRP | Fluorine plastic insulation silicone rubber sheath copper wire woven split screen aggregation shielding precision levelKDividing thermocouple with compensation soft cable |
Note:1Or more basic models only listed copper or tin silk screen, other shielding type type need to change the shielding can, such asP2、P3 2 Flame retardant added in front of the modelZRAnd after, armored cable models22,ZR192For the importPFAMaterials, heat resistance260℃ |
4: this Ann model compensating cable
IA-KX-GA-FPVP | Fluorine plastic insulated PVC sheathed wire woven split screen aggregation shielding precision levelKIndex number this Ann type thermocouple compensating cable |
IA-KX-GA-FPVRP | Fluorine plastic insulated PVC sheathed wire woven split screen aggregation shielding precision levelKDividing the Ann type thermocouple with compensation soft cable |
IA-KX-HA-FPFP | Fluorine plastic insulated and sheathed wire woven split screen aggregation shielding precision levelKIndex number this Ann type thermocouple compensating cable |
IA-KX-HA-FPFRP | Fluorine plastic insulated and sheathed wire woven split screen aggregation shielding precision levelKDividing the Ann type thermocouple with compensation soft cable |
IA-KX-HA-FPGP | Fluorine plastic insulation silicone rubber sheath copper wire woven split screen aggregation shielding precision levelKIndex number this Ann type thermocouple compensating cable |
IA-KX-HA-FPGRP | Fluorine plastic insulation silicone rubber sheath copper wire woven split screen aggregation shielding precision levelKDividing the Ann type thermocouple with compensation soft cable |
Note:1Or more basic models only listed copper or tin silk screen, other shielding type type need to change the shielding can, such asP2、P3 2 Flame retardant added in front of the modelZRAnd after, armored cable models22,ZR192For the importPFAMaterials, heat resistance260℃ |
5: code name and meaning
table2
project | Code name | instructions |
Flame retardant properties | ZR | pointsA, B, C grade flame retardant |
A series of codes | /IA | There is no(The Ann model) |
Insulation materials | Y | polyethylene |
YJ | Crosslinked polyethylene | |
YD | Low smoke zero halogen flame retardant polyolefin | |
F | fep(F46) or soluble polytetrafluoroethylene (PFA) | |
Sheath material | YD | Low smoke zero halogen flame retardant polyolefin |
V | Polyvinyl chloride (PVC) | |
F | fep(F46) or soluble polytetrafluoroethylene (PFA) | |
G | Silicone rubber | |
Shielding materials | P | Copper wire braided shielding |
P2 | Copper strip winding and shielding | |
P3 | Lu: su composite belt winding and shielding | |
Conductor structure | A | Single strand conductors |
B | 7 strands of stranded conductor | |
R | Stranded conductor |