Special cable
tezhongdianlan
PE polyethylene insulated power cable
Browse:
Add Time: 2016-08-20 15:46:09
Recommendation:
PE polyethylene insulated power cable的产品详细介绍:

PE Cross-linked polyethylene insulating power cable



Product features:1, the product use: this product is suitable for rated voltage (U0 / U) for 3.6/6 to 26/35 kv power line, for power transmission and distribution can be.2, product standards: GB12706-91 rated voltage up to and including 35 kv copper, aluminium, plastic insulated power cable.3, product use features: (1) the cable under the condition of the environment temperature is not lower than 0 ℃, laying without heating in advance.Cable head of unrestricted.(2) the cable core long-term allowed working temperature shall not exceed the following provisions: outer sheath is PVC cable is 90 ℃;Outer sheath is polyethylene jacket of the cable is 80 ℃.(3) wire core when short circuit (the longest 5 s) temperature shall not exceed 250 ℃ (4) when cable laying, the minimum bending radius rules are as follows: single core cable: 20 (d + d) + / - 5%;Three core cable: 15 (d + d) plus or minus 5%.For the actual diameter of the cable type: D, D is the actual outer diameter of the conductor.4, product model, name and scope of use

Type no.The name saysUsing range
Copper coreAluminum conductor
YJVYJLVCross-linked polyethylene insulated PVC sheathed power cableFixed installation, indoor, in cable trench, tunnel or underground in the air
YJYJYLYCross-linked polyethylene insulated, PE sheathed power cableFixed for laying indoors, in cable trench, tunnel or underground
YJV22YJLV22Cross-linked polyethylene insulating tape armored PVC sheathed power cableFixed installation in the places where outside pressure
YJV23YJLV23Cross-linked polyethylene insulating tape armored PE sheathed power cableThe place of fixed installation in common external force
YJV32YJLV32Cross-linked polyethylene insulated fine steel wire armored PVC sheathed power cableFixed installation in requirements can withstand the tension
YJV33YJLV33Cross-linked polyethylene insulated fine steel wire armoured PE sheathed power cableFixed installation in requirements can withstand the tension
YJV42JYLV42Cross-linked polyethylene insulation thick steel wire armoured PVC sheathed power cableFixed installation, well or underwater requirements can withstand the tension
YJV43YJLV43Cross-linked polyethylene insulation thick steel wire armoured PE sheathed power cableFixed installation in can bear larger tension

Note: one or two single core cable in the iron pipes are not allowed.

5, the production of

model
some
The rated voltage U0 / U KV
3.6/6 6/66/10 8.7/1012/20 18/2021/35 26/35

Conducting wire core of nominal section (was)

YJLV
YJV
YJLY
YJY
125-500.25-500.35-500.50-300.
YJLV32
YJV32
YJLY32
JYY32
125-500.25-500.35-500.50-300.
YJLV42
YJV42
YJLV43
YJV43
125-500.25-500.35-500.50-300.
YJLV
YJV
YJLY
YJY
325-300.25-300.35-300.-
YJLV22
YJV22
YJLV23
YJV23
325-300.25-300.35-300.-
YJLV32
YJV32
YJLV33
YJV33
325-300.25-300.35-300.-
YJLV42
YJV42
YJLV43
YJV43
325-300.25-300.35-150.