Welcome to Anhui Xin Huan Neng Electrical Co., LTD.
    RSS | Site map|disclaimer|中文版
Anhui  Xin Huan Neng Electrical Co., LTD.
freephone

0550-7989777

Popular Keywords:
联系我们
    全国咨询热线:0550-7989777
  • Mobile:18019898888
  • Email:xhn@ahxhn.cn
  • Address:69, second road, Tianchang economic development zone, Anhui province
Special cable
tezhongdianlan
Flame retardant cable
Browse:
Add Time: 2016-08-20 15:48:33
Recommendation:
Flame retardant cable的产品详细介绍:

flame retardant cable due to cable line about the dangers of fire, to all countries in the world put the flame retardancy of the cable in the increasingly important position, I company production of flame retardant cable are shown in table 1 to 3.
Table 1: flame retardant plastic insulated control cable
Execution standard: GB/T18308.3-2001 GB 9330-9330
Model: ZR - KVV
Rated voltage: 450/750
Some conclusions: 2-61
Nominal cross section: 0.5 to 6.0

Cable in indoor, can be inside the tunnel in cable trench, bridge, underground, the occasion of flammable cables cannot bear tension and stress.
Is fit for ac rated voltage U0 / U = 450/750 v power supply, monitoring and so on in the loop.
Cable conductor of the highest working temperature is 70 ℃ when the short circuit, cable conductor highest temperature does not exceed 160 ℃ (duration is not more than 5 s)
Cable allowed bending radius should not less than 15 D note: D for mm outer diameter.
When the cable laying temperature not lower than 0 ℃
Flame retardant category is divided into A, B, C.
Note: according to user needs to produce flame retardant crosslinking type, control cable, power cable.
ZR-KVVP
ZR-KVVP2
ZR-KVV22
ZR-KVV32
ZR-KVVP
ZR-KVVRP
Table 2: flame retardant plastic insulated power cable
Execution standard: GB/T18308.3-2001 GB 12706-12706
The product name
model
Product specification was
Some product structure
Use occasions
Use the feature

Copper core
Aluminum conductor
Copper core
Aluminum conductor

PVC insulated PVC sheathed, flame retardant power cable
ZR-VV
ZR-VLV
1.5-630
2.5-630
Single core, second-class core core, third, fourth, five such as core, core 3 + 1, 4, 3 + 2 + 1 core core
Cable can be laid in the important engineering, facilities, power distribution system, cable has flame retardant performance, flammable, the cable can't bear tension and stress.
Is fit for ac rated voltage U0 / U = 0.6/1 kv power supply circuit.
Cable conductor of the highest working temperature is 70 ℃ when the short circuit, cable conductor highest temperature does not exceed 160 ℃ (duration is not more than 5 s)
Cable allowed bending radius should not less than 15 D note: D for mm outer diameter.
When the cable laying temperature not lower than 0 ℃
Flame retardant category is divided into A, B, C.
Note: according to user needs to produce flame retardant crosslinking type, control cable, power cable.

PVC insulated steel tape armoured and PVC sheathed, flame retardant power cable


Return To The Top