Product description:
WIDEPLUS-LT series flange level transmitter adopts high performance pressure sensor with wide adaptability.
Product features
·: measurement of the level of an open or sealed container
· liquid level measurement accuracy 0.25%
· measuring range: 6kPa~2.0MPa
· 3-, 4- inch flat diaphragm or extended diaphragm
· a variety of filling fluid selection, can meet a variety of application requirements
· adjustable damping
· connection material: stainless steel, Hastelloy C-276 and tantalum
Working principle
When working, the high and low pressure side of the isolation membrane and the filling liquid transfer the process pressure to the center of the filling liquid, the center of the filling liquid will be transferred to the pressure δ &mdash. The sensing membrane is a elastic element of tension, the displacement changing as differential pressure (atmospheric pressure gauge transmitter for GP, as applied in the low voltage side of the sensing membrane.). AP absolute pressure transmitter, low pressure side always maintains a reference pressure. The maximum displacement of the sensing diaphragm is 0.004 inches (0.10 mm). And the displacement is proportional to the pressure. The capacitance plate on both sides detects the position of the sensing diaphragm. The capacitance difference between the sensing film and the capacitance plate is converted to the desired current, voltage or digital HART (high speed addressable remote transmitter data highway) output signal.
technical parameter
Measurement of dielectric liquids, gases and vapors
Range range differential pressure: 0 ~ 0.16kPa to 0 ~ 10MPa
Relative pressure: maximum 0 ~ 40MPa minimum of 0 ~ 0.16kPa
Absolute pressure: maximum 0 ~ 10MPa minimum of 0 ~ 10kPa
Working voltage 12V ~ 45V DC (generally use 24V DC)
Output signal 4mA ~ 20mA DC
Explosion-proof grade · flameproof (EXdIIBT5 or ExdIICT6) · intrinsically safe (EXibIICT6 or ExiaIICT6)
Range and zero external continuous adjustable
Positive and negative migration of its output regardless of the scale, positive and negative migration, the upper and lower limits shall not exceed the limits of the range
· the maximum forward migration is the minimum adjustment range of 500%
· the maximum negative migration is the minimum adjustment range of 600%
When the damping is filled with silicone oil, 0.25s ~ 1.67s can be adjusted continuously
Start time 2S (no preheating)
Ambient temperature range -20 DEG C to 70 C
Accuracy level 0.2, level 0.5
Relative humidity 0 ~ 100%RH
Stability is better than 0.1FS/
The volume change of the sensor is less than 0.16cm
The · LED digital display indicator; · LCD · LCD; linear indicator display
Power change less than the output range of 0.0059%/V
The influence of vibration on any axis, the frequency is 200Hz, the maximum error caused by the range of ± 0.05%/g
Medium temperature -40 C ~ 100 C
Storage temperature -40 C ~ 100 C
Temperature effect 1, maximum range
Zero error: range ± 0.5%/55 C
Total error: 1.0%/55 of the range ±
2, minimum range
Zero error: range ± 3.0%/55 C
Total error: 3.5%/55 of the range ±
The weight of 4.9kg (not including optional)