Power station thermocouple/thermal resistance
Browse:
Add Time: 2016-08-18 15:38:33
Recommendation:
Power station thermocouple/thermal resistance的产品详细介绍:

1, the application

Professional for power station design, can satisfy 300000, 600000 kw generators and auxiliary engine temperature measurement needs.Direct measurement of all kinds of production process - 200 ° C to 800 ° C range of liquid, steam and gas medium, as well as solid surface temperature.

2, work principle,

The thermocouple electrode is composed of two different conductor material.When measuring the temperature difference is with the reference, the can produce thermoelectric power, the instrument Then show the thermoelectric potential have corresponding temperature value.Thermal resistance is the use of the material when the temperature changes, its resistance also along with the change of characteristics to measure temperature.When resistance changes, the work shows the temperature resistance of the meter.

3, the main technical parameters

Product standards:
IEC584
IEC751
IEC1515
JB/T18622-1997
JB/T8623-1997
GB/T16839-1997

4, measurement range and tolerance

Type no.Degree,Tolerance level
III
Tolerance valuesTemperature measurement range ° c.Tolerance valuesTemperature measurement range ° c.
WRNK±1.5°C- 40 ~ + 375±2.5 °C- 40 ~ + 333
±0.004ltl375 ~ 1000±0.0075 ltl333 ~ 1200
WRMN±1.5°C- 40 ~ + 375±2.5°C- 40 ~ + 333
±0.004 ltl375 ~ 1000±0.0075 ltl333 ~ 1200
WREE±1.5°C- 40 ~ + 375±1.5°C- 40 ~ + 333
±0.004 ltl375 ~ 800±0.004 ltl333 ~ 900
WRFJ±1.5°C- 40 ~ + 375±1.5°C- 40 ~ + 333
±0.004 ltl375 ~ 750±0.004 ltl333 ~ 750
WRCT±1.5°C- 40 ~ + 125±1°C- 40 ~ + 133
±0.004 ltl125 ~ 350±0.0075 ltl133 ~ 350


5, room temperature insulation resistance

Thermal resistance at ambient temperature for 15-35 ° C, relative humidity is not more than 80%, test voltage for 10-100 - v (dc) electrode and outer casing of the insulation resistance between > 100 m omega.

Thermocouple in the environmental temperature is 20 + 15 ° C, relative humidity is not more than 80%, test voltage for 500 + 50 v (dc) electrode and outer casing of the insulation resistance between > 1000 omega. M